AS2000 Continuous Emission Monitoring System

AS2000 Continuous Emission Monitoring System
Product Detailed
Related Categories:Testing Equipment
Introduction AS-2000 comprises sampling subsystem, gas measuring subsystem, smoke measuring subsystem, auxiliary parameter meas

Features

l         Automatic analyzing the concentration of one or more components of the concentration of SO2,NO,CO,CO2,O2,C2H4 and gaseous pollutant in the mix gas, but also detecting the discharge flue dust in the fume and the monitoring of process parameters;

l         Measuring results will be stored in the data sampling control system automatically;

l          All kinds of ways of transmission can be compatible, multi-levels networking;

l         Standard modular design, easy to maintain, upgrade and expand;

l         CEMS system can be self-diagnosed, including invalid probe and detecting source, range exceed alarm, breakdown of main units alarm, timely fault notice during the operation;

l         Site data timely transferred, fault remote diagnosis;

l         Auto-calibration zero by air(<3%CO2 must use N2 calibration zero);

l         Data can be collected, stored, handled and distinguished by data system, which can control the daily construction of CEMS, including cycling auto-correction, auto-reverse blowing probe and filter of sampling system, providing the information what approved test and monitoring needed;

l         Multichannel 4~20MA analog output and relay contact output;

——high-accuracy, stable

——short preheating time-5mins

——bilingual menu operation

——User can do the man-machine interaction through keyboard and LCD in the front  

——system can non-stop operate at least 90 days with no need for daily maintenance

——Interval time: one adjusting every 1-6 months according to environmental condition

——easy to use, operate and set, low-cost, low work load for maintain

Specifications

Item

Specifications

Measuring elements

SO2,NOx or O2 (according to user’s requirements, no O2 sometimes)

Measuring range

SO2     0 ~ 2500mg/m3

NOx     0 ~ 2500 mg/m3

O2     0 ~ 25vol%

Repeatability

Each gas component, respective range±0.5%(FS)

Digital display drift

Each gas component, respective range within ±1%

Zero drift

Each gas component, respective range within ±2%/weeks

Drift

Each gas component, respective range within ±2%/weeks

Linearity

Each gas component, respective range within ±2%/

Response time

Each gas component, its respective measuring range within 100 seconds, but SO2 within 240 seconds

Stability relative to ambient temperature

The temps changes within ±5°C, satisfied the specified value of zero drift and span drift

Quantity of sample

About 3L/min

Method of correction

manual

automatic:(0~999 hour)

Gas revise

Zero gas     100%N2   standard gas

Span gas   SO2 in N2 standard gas

           NO in N2   standard gas

           O2 in N2   standard gas or air)

Enable condition

Temp.:-5 ~ 40°C.Humidity:95%RH below, no radiation

Direct sunlight, the place with more vibratory

External input and output

Applied in the circumstance of power-off, maintenance, analyzer alarm, correction and others

Voltage

AC380V±22V,50/60Hz(optional)about 40A

size

overall dimension drawing for reference

weight

About 200Kg

Material of connected parts

Polyethylene, glasses, Teflon, Viton

Await sample gas pressure

-1Kpa ~ +1Kpa

Standard sample gas

Temp.:400°C below

Dust:0.1g/Nm3

SO2:2500mg/m3 below

NOx:2500 mg/m3 below

H2O:0.8 ~ 80wt%

Storage

Surrounding Temp.:-20 ~ 60°C

Humidity:60% below

Others: cannot be stored in the air of corrosive ( shall open the package, on the breezy place

Applications

Monitoring the waste gas emission from Power Generation, Thermal Power, Iron and Steel, Petrochemical, Cement, Waste Power, Desulphurization and Denitrification, Tobacco, Paper and so on.

AS2000 Continuous Emission Monitoring System



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.