- Security Services[10]
- Level Measuring Instruments[8]
- Other Police & Military Supplies[5]
- Other Security & Protection Products[1]
- Other Surveillance Products[1]
- Industrial Metal Detectors[1]
- Alarm[2]
- Access Control System[9]
- Other Environmental Products[10]
- Wireless Networking Equipment[1]
- CCTV Monitor[3]
- Noise Reduction Device[1]
- Water Treatment[7]
- Gas Disposal[5]
- Testing Equipment[3]
- Other Analysis Instruments[3]
- Measuring & Analysing Instrument Processing Services[6]
- Carbon Analyzers[1]
- Microscopes[9]
- Contact Person : Ms. Song Alice
- Company Name : China Sciences MapUniverse Technology Co., Ltd.
- Tel : 86-10-51286880-313
- Fax : 86-10-51286880-801
- Address : Beijing,Beijing,F2 Tower B Venture Plaze, No.11 Anxiangbeili Street, Chaoyang District.
- Country/Region : China
- Zip : 100101
AS2000 Continuous Emission Monitoring System
Features
l Automatic analyzing the concentration of one or more components of the concentration of SO2,NO,CO,CO2,O2,C2H4 and gaseous pollutant in the mix gas, but also detecting the discharge flue dust in the fume and the monitoring of process parameters;
l Measuring results will be stored in the data sampling control system automatically;
l All kinds of ways of transmission can be compatible, multi-levels networking;
l Standard modular design, easy to maintain, upgrade and expand;
l CEMS system can be self-diagnosed, including invalid probe and detecting source, range exceed alarm, breakdown of main units alarm, timely fault notice during the operation;
l Site data timely transferred, fault remote diagnosis;
l Auto-calibration zero by air(<3%CO2 must use N2 calibration zero);
l Data can be collected, stored, handled and distinguished by data system, which can control the daily construction of CEMS, including cycling auto-correction, auto-reverse blowing probe and filter of sampling system, providing the information what approved test and monitoring needed;
l Multichannel 4~20MA analog output and relay contact output;
——high-accuracy, stable
——short preheating time-5mins
——bilingual menu operation
——User can do the man-machine interaction through keyboard and LCD in the front
——system can non-stop operate at least 90 days with no need for daily maintenance
——Interval time: one adjusting every 1-6 months according to environmental condition
——easy to use, operate and set, low-cost, low work load for maintain
Specifications
Item | Specifications |
Measuring elements | SO2,NOx or O2 (according to user’s requirements, no O2 sometimes) |
Measuring range | SO2 0 ~ 2500mg/m3 NOx 0 ~ 2500 mg/m3 O2 0 ~ 25vol% |
Repeatability | Each gas component, respective range±0.5%(FS) |
Digital display drift | Each gas component, respective range within ±1% |
Zero drift | Each gas component, respective range within ±2%/weeks |
Drift | Each gas component, respective range within ±2%/weeks |
Linearity | Each gas component, respective range within ±2%/ |
Response time | Each gas component, its respective measuring range within 100 seconds, but SO2 within 240 seconds |
Stability relative to ambient temperature | The temps changes within ±5°C, satisfied the specified value of zero drift and span drift |
Quantity of sample | About 3L/min |
Method of correction | manual automatic:(0~999 hour) |
Gas revise | Zero gas 100%N2 standard gas Span gas SO2 in N2 standard gas NO in N2 standard gas O2 in N2 standard gas or air) |
Enable condition | Temp.:-5 ~ 40°C.Humidity:95%RH below, no radiation Direct sunlight, the place with more vibratory |
External input and output | Applied in the circumstance of power-off, maintenance, analyzer alarm, correction and others |
Voltage | AC380V±22V,50/60Hz(optional)about 40A |
size | overall dimension drawing for reference |
weight | About 200Kg |
Material of connected parts | Polyethylene, glasses, Teflon, Viton |
Await sample gas pressure | -1Kpa ~ +1Kpa |
Standard sample gas | Temp.:400°C below Dust:0.1g/Nm3 SO2:2500mg/m3 below NOx:2500 mg/m3 below H2O:0.8 ~ 80wt% |
Storage | Surrounding Temp.:-20 ~ 60°C Humidity:60% below Others: cannot be stored in the air of corrosive ( shall open the package, on the breezy place |
Applications
Monitoring the waste gas emission from Power Generation, Thermal Power, Iron and Steel, Petrochemical, Cement, Waste Power, Desulphurization and Denitrification, Tobacco, Paper and so on.